There is a signifcant amendment on FAR-25 by FAA in 2007, H section which contains 17 rules was added to define the requirements for Electrical Wiring Interconnection System (EWIS), FAR-26 was released for continued airworthiness and safety.All new commercial aircraft should be designed according to the airworthiness for EWIS.This article analyzed methods to meet EWIS airworthiness requirements in design, by comparing EWIS requirements to old standards, preparing for compliance plan and continued airworthiness instructions.
[1]陈荣, 钟栋梁, 傅国如.空中电缆着火故障分析[J].中国科技论文在线, 2006(8):54-56.
[2]中国民用航空总局.CCAR 25R4-2010运输类飞机适航标准[S].2010.
[3]陈巴生, 蒋瑞.运输类飞机适航条例的重大修正[J].民用飞机设计与研究, 2007(4):38-40.v[4]中国民用航空总局.CCAR 25R3-2001运输类飞机适航标准[S].2001.
[5]中国民用航空总局.CCAR 21R3-2007民用航空产品和零部件合格审定规定[S].2007.
[6]Federal Aviation Administration.AC25 1701-1-2007 Certification of Electrical Wiring Interconnection Systems on Transport Category Airplanes[S].2007.
[7]徐浩军.航空器适航性概论[M].西安:西北工业大学出版社, 2012.
[8]中国民用航空总局.CCAR 26-2011运输类飞机的持续适航和安全改进规定[S].2011.